Chin. Phys. Lett.  2015, Vol. 32 Issue (03): 030701    DOI: 10.1088/0256-307X/32/3/030701
GENERAL |
An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors
HU Kun1,2,3, LI Feng1,2, CHEN Lian1,2, LIANG Fu-Tian4, JIN Ge1,2**
1State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026
2Department of Modern Physics, University of Science and Technology of China, Hefei 230026
3 No.38 Research Institute, China Electronics Technology Group Corporation, Hefei 230088
4Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026
Cite this article:   
HU Kun, LI Feng, CHEN Lian et al  2015 Chin. Phys. Lett. 32 030701
Download: PDF(622KB)  
Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. The method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140 μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection.
Published: 26 February 2015
PACS:  07.05.Hd (Data acquisition: hardware and software)  
  29.40.Gx (Tracking and position-sensitive detectors)  
  42.72.Bj (Visible and ultraviolet sources)  
TRENDMD:   
URL:  
https://cpl.iphy.ac.cn/10.1088/0256-307X/32/3/030701       OR      https://cpl.iphy.ac.cn/Y2015/V32/I03/030701
Service
E-mail this article
E-mail Alert
RSS
Articles by authors
HU Kun
LI Feng
CHEN Lian
LIANG Fu-Tian
JIN Ge
[1] Dong J, Hu B T, Chen Y B and Xie Y G 2009 Chin. Phys. B 18 4229
[2] Yan Q R, Zhao B S, Yang H, Liu Y A, Zhu X P and Li M 2010 Acta Phys. Sin. 59 6164 (in Chinese)
[3] Sandel B R et al 2000 Space Sci. Rev. 91 197
[4] Sobue S et al 2009 Recent Patents Space Technol. 1 12
[5] Wang Z L, Wang G Y and Bao X L 2008 Chin. Phys. B 17 3596
[6] Gao B, Yu X F, Ren D Y, Li Y D, Cui J W, Li M S, Li M and Wang Y Y 2011 Acta Phys. Sin. 60 036106 (in Chinese)
[7] Guo J B, Xu X Z, Shi Q H and Hu T H 2013 Acta Phys. Sin. 62 110508 (in Chinese)
[8] Vencelj M Bucar K Novak R and Wortche H 2009 Nucl. Instrum. Methods Phys. Res. Sect. A 607 581
[9] Belli F, Esposito B, Marocco D, Riva M, Kaschuck Y, Bonheure G and Efda J 2008 Nucl. Instrum. Methods Phys. Res. Sect. A 595 512
[10] Martin C Jelinsky P Lampton M and Malina R F 1981 Rev. Sci. Instrum. 52 1067
[11] Frank Ogletree D Blackman G S Hwang R G and Starke U 1992 Rev. Sci. Instrum. 63 104
[12] Grinyer G F et al 2007 Nucl. Instrum. Methods Phys. Res. Sect. A 579 1005
Related articles from Frontiers Journals
[1] HU Kun, LU Hou-Bing, WANG Xu, LI Feng, HAN Liang, JIN Ge. The Improved Design of Multi-channel Thin Gap Chamber Simulation Signal Source for the ATLAS Detector Upgrade[J]. Chin. Phys. Lett., 2015, 32(08): 030701
Viewed
Full text


Abstract