FUNDAMENTAL AREAS OF PHENOMENOLOGY(INCLUDING APPLICATIONS) |
|
|
|
|
Effects of Different Zernike Terms on Optical Quality and Vision of Human Eyes |
ZHAO Hao-Xin1,2, XU Bing1, LI Jing3, DAI Yun1, YU Xiang1, ZHANG Yu-Dong1, JIANG Wen-Han1 |
1Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 6102092Graduate School of the Chinese Academy of Sciences, Beijing 1000493Beijing Tongren Hospital, Capital Medical University, Beijing 100730 |
|
Cite this article: |
ZHAO Hao-Xin, XU Bing, LI Jing et al 2009 Chin. Phys. Lett. 26 054205 |
|
|
Abstract The visual quality of human eyes is much restricted by high-order aberrations as well as low-order aberrations (defocus and astigmatism), but each term of high-order aberrations contributes differently. The visual acuity and contrast of the image on the retina can be gained by inducing aberrations to each term of high orders. Based on an adaptive optics system, the visual acuity of four subjects is tested by inducing aberrations to each Zernike term after correcting all the aberrations of the subjects. Zernike terms near the center of the Zernike tree affect visual quality more than those near the edge both theoretically and experimentally, and 0.1-μm aberration of these terms can clearly degrade the optical quality and vision. The results suggest that correcting the terms near the center of Zernike tree can improve the visual quality effectively in practice.
|
Keywords:
42.66.Si
42.15.Fr
42.66.-p
|
|
Received: 26 December 2008
Published: 23 April 2009
|
|
PACS: |
42.66.Si
|
(Psychophysics of vision, visual perception; binocular vision)
|
|
42.15.Fr
|
(Aberrations)
|
|
42.66.-p
|
(Physiological optics)
|
|
|
|
|
[1] Atchison D A 1992 Appl. Opt. 31 3579 [2] Liang J Z, Williams D R and Miller D T 1997 J. Opt.Soc. Am. A 14 2884 [3] Kennedy G T and Paterson C 2007 Opt. Commun. 271 278 [4] Navarro R, Moreno-Barriuso E, Bara S and Mancebo T 2000 Opt. Lett. 25 236 [5] Fernandez-Sanchez V, Eugenia Ponce M, Lara F, Montes-MicoR, Castejon-Mochon J F and Lopez-Gil N 2008 J. Cataract.Refract. Surg. 34 1339 [6] Applegate R A, Ballentine C, Hillery G, Sarver E J andSarver C A 2003 Optometry and Vision Science 80 97 [7] Xue L X, Rao X J, Ling N and Jiang W H 2007 Acta Opt.Sin. 27 893 (in Chinese) [8] Wang Y, Wang Z Q, Guo H Q and Quan W 2005 Acta Opt.Sin. 25 1519 (in Chinese) [9] Porter J, Guirao A, Cox L G and Williams D R 2001 J.Opt. Soc. Am. A 18 1793 [10] Zhao H X, Xu B, Xue L X, Dai Y, Liu Q and Rao X J 2008 Chin. Phys. Lett. 25 1309 |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|