Abstract A photoacoustic system with an annular transducer array is presented for rapid, high-resolution photoacoustic tomography of animals. An eight-channel data acquisition system is applied to capture the photoacoustic signals by using multiplexing and the total time of data acquisition and transferring is within 3 s. A limited-view filtered back projection algorithm is used to reconstruct the photoacoustic images. Experiments are performed on a mouse head and a rabbit head and clear photoacoustic images are obtained. The experimental results demonstrate that this imaging system holds the potential for imaging the human brain.
|
|
Published: 30 June 2014
|
|
PACS: |
43.35.+d
|
(Ultrasonics, quantum acoustics, and physical effects of sound)
|
|
87.57.C-
|
(Image quality)
|
|
43.60.+d
|
(Acoustic signal processing)
|
|
43.80.+p
|
(Bioacoustics)
|
|
|
|
|
[1] Hoelen C G A, Mul de F F M, Pongers R and Dekker A 1998 Opt. Lett. 23 648 [2] Wang X, Pang Y, Ku G, Xie X, Stoica G and Wang L V 2003 Nat. Biotechnol. 21 803 [3] Yin B Z, Xing D, Wang Y, Zeng Y G, Tan Y and Chen Q 2004 Phys. Med. Biol. 49 1339 [4] Yang D W, Xing D, Gu H M, Tan Y and Zeng L M 2005 Appl. Phys. Lett. 87 194101 [5] Yang D W, Xing D, Tan Y, Gu H M and Yang S H 2006 Appl. Phys. Lett. 88 174101 [6] Yang D W, Xing D, Yang S H and Xiang L Z 2007 Opt. Express 15 15566 [7] Zeng L M, Xing D, Gu H M, Yang D W, Yang S H and Xiang L Z 2007 Med. Phys. 34 556 [8] Razansky D, Vinegoni C and Ntziachristos V 2007 Opt. Lett. 32 2891 [9] Zeng L M, Liu G D, Yang D W and Ji X R 2012 Opt. Express 20 1237 [10] Zeng L M, Liu G D, Yang D W and Ji X R 2013 Appl. Phys. Lett. 102 053704 [11] Yang D W, Zeng L M, Pan Ch N, Zhao X H and Ji X R 2013 Opt. Express 21 984 [12] Cox B, Laufer J G, Arridge S R and Beard P C 2012 J. Biomed. Opt. 17 061202 [13] Cai X, Li W, Kim C H, Yuan Y, Wang L H and Xia Y 2011 ACS Nano 5 9658 [14] Tan Z L, Tang Z L, Wu Y B, LiaoY F, Dong W and Guo L N 2011 Opt. Express 19 2426 [15] Zhang Y, Cai X, Yao J, Xing W, Wang L H and Xia Y 2014 Angew. Chem. Int. Ed. 53 184 [16] Yao J, Wang L, Li C, Zhang C and Wang L V 2014 Phys. Rev. Lett. 112 014302 [17] Xing W, Wang L, Maslov K I and Wang L V 2013 Opt. Lett. 38 52 [18] Biswal B B, Mennes M, Zuo X N, Gohel S and Kelly C 2010 Proc. Natl Acad. Sci. 107 4734 [19] Boas D A, Dale A M and Franceschini M A 2004 Neuroimaging 23 S275 [20] Smith S W, Chu K,. Idriss S F, N Ivancevich M, Light E D and Wolf P D 2004 Ultrasound Med. Biol. 30 1365 [21] Gamelin J, Maurudis A, Aguirre A, Huang F, Guo P, Wang L H and Zhu Q 2009 Opt. Express 17 10489 [22] Zhou Q, Ji X R and Xing D 2011 Med. Phys. 38 1561 [23] Wang L H and Hu S 2012 Science 335 1458 [24] Nie L, Guo Z and Wang L H 2011 J. Biomed. Opt. 16 076005 [25] Nie L, Cai X, Maslov K, Garcia-Uribe A, Anastasio M A and Wang L H 2012 J. Biomed. Opt. Lett. 17 110506 [26] Yang X and Wang L V 2008 J. Biomed. Opt. Lett. 13 044009 [27] Wang Y, Xing D, Zeng Y G and Chen Q 2004 Phys. Med. Biol. 49 3117 [28] Gonzates R, Woods R and Eddins S 2003 Digital Image Processing Using MATLAB (Upper Saddle River, New Jersey: Prentice Hall) [29] Kruger R A, Reinecke D and Kruger G 1999 Med. Phys. 26 1832 |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|