ATOMIC AND MOLECULAR PHYSICS |
|
|
|
|
Improvement on Temperature Measurement of Cold Atoms in a Rubidium Fountain |
LÜ De-Sheng**, QU Qiu-Zhi, WANG Bin, ZHAO Jian-Bo, LIU Liang**, WANG Yu-Zhu
|
Key Laboratory for Quantum Optics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800
|
|
Cite this article: |
LÜ, De-Sheng, QU Qiu-Zhi et al 2011 Chin. Phys. Lett. 28 063201 |
|
|
Abstract The time-of-flight (TOF) method is one of the most common ways to measure the temperature of cold atoms. In the cold atomic fountain setup, the geometry of the probe beam will introduce the measurement errors to the spatial distribution of cold atomic cloud, which will lead to the measurement errors on atomic temperature. Using deconvolution, we recover the atomic cloud profile from the TOF signal. Then, we use the recovered signals other than the TOF signals to obtain a more accurate atomic temperature. This will be important in estimating the effects of cold atom collision shift and the shift due to transverse cavity phase distribution on an atomic fountain clock.
|
Keywords:
32.30.Bv
|
|
Received: 26 January 2011
Published: 29 May 2011
|
|
PACS: |
32.30.Bv
|
(Radio-frequency, microwave, and infrared spectra)
|
|
|
|
|
[1] Sorties Y, Bize S, Nicolas C, Clairon A, Salomon C and Williams C 2000 Phys. Rev. Lett. 85 3117
[2] Kokkelmans S J J M F, Verhaar B J, Gibble K and Heinzen D J 1997 Phys. Rev. A 56 R4389
[3] Li R X and Gibble K 2004 Metrologia 41 376
[4] Lett P D, Watts R N, Westbrook C I, Phillips W D, Gould P L and Metcalf H J 1988 Phys. Rev. Lett. 61 169
[5] Weiss D S, Riis E, Shevy Y, Ungar P J and Chu S 1989 J. Opt. Soc. Am. B 6 2072
[6] Brzozowski T M, Maczynska M, Zawada M Zachorowski J and Gawlik W 2002 J. Opt. B 4 62
[7] Zhou Z C, Wei R, Shi C Y, Lü D S, Li T and Wang Y Z 2009 Chin. Phys. Lett. 26 123201
[8] Gerginov V, Nemitz N, Weyers S, Schroder R, Griebsch D and Wynands R 2010 Metrologia 47 65
[9] Bize S, Laurent P, Abgrall M et al 2004 Physique 5 829
[10] Lü D S, Wang B, Li T and Liu L 2010 Chin. Opt. Lett. 8 735
[11] Laurent P, Abgrall M, Jentsch C et al 2006 Appl. Phys. B 84 683
[12] Lü D S, Qu Q Z, Wang B, Zhao J B, Li T, Liu L, Wang Y Z 2011 Chin. Phys. B 20 063201
[13] Dalibard J and Cohen-Tannoudji C 1989 J. Opt. Soc. Am. B 6 2023
[14] Zheng J L, Ying Q Y and Yang W L 2000 Signals and Systems 2nd edn (Beijing, Higher Education Press) vol 2 (in Chinese)
[15] Wang B, Lu D S, Qu Q Z, Zhao J B, Li T, Liu L and Wang Y Z 2011 Chin. Phys. Lett. 28 063701
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|