Original Articles |
|
|
|
|
Optimization of a Cryogenic System at Temperature 2K for the PKU-FEL Facility |
HAO Jian-Kui;LIN Lin;HUANG Sen-Lin;ZHAO Kui |
MOE Key Laboratory of Heavy Ion Physics, Institute of Heavy Ion Physics, Peking University, Beijing 100871 |
|
Cite this article: |
HAO Jian-Kui, LIN Lin, HUANG Sen-Lin et al 2006 Chin. Phys. Lett. 23 2674-2677 |
|
|
Abstract The conceptual design of a cryogenic system at temperature 2K for the Peking University Free Electron Laser (PKU-FEL) facility is carried out. In order to minimize the scale of the cryogenic system and the running cost, the superconducting accelerator and the superconducting injector will mainly run at a long-pulsed mode. Optimization of the 2-K cryogenic system is carried out based on the heat load estimation and running parameters. Total cooling power of 52.5W for the long-pulsed mode is necessary for the PKU cryogenic system. The PKU cryogenic system will be the first 2-K system for accelerators in China and will provide experience for similar facilities.
|
Keywords:
07.20.Mc
74.25.Nf
|
|
Published: 01 October 2006
|
|
PACS: |
07.20.Mc
|
(Cryogenics; refrigerators, low-temperature detectors, and other low-temperature equipment)
|
|
74.25.Nf
|
|
|
|
|
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|