Frequency Measurement of the Electric Quadrupole Transition in a Single Laser-Cooled 40Ca+
LIU Qu1,2,3, HUANG Yao1,2,3, CAO Jian1,2,3, OU Bao-Quan1,2,4, GUO Bin1,2**, GUAN Hua1,2, HUANG Xue-Ren1,2***, GAO Ke-Lin1,2***
1State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics (WIPM), Chinese Academy of Sciences, Wuhan 430071 2Centers for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071 3Graduate School of the Chinese Academy of Sciences, Beijing 100049 4Department of Physics, Science College, National University of Defense Technology, Changsha 410073
Frequency Measurement of the Electric Quadrupole Transition in a Single Laser-Cooled 40Ca+
LIU Qu1,2,3, HUANG Yao1,2,3, CAO Jian1,2,3, OU Bao-Quan1,2,4, GUO Bin1,2**, GUAN Hua1,2, HUANG Xue-Ren1,2***, GAO Ke-Lin1,2***
1State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics (WIPM), Chinese Academy of Sciences, Wuhan 430071 2Centers for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071 3Graduate School of the Chinese Academy of Sciences, Beijing 100049 4Department of Physics, Science College, National University of Defense Technology, Changsha 410073
摘要The optical frequency of the
4s2S1/2–3d2D5/2 transition in a single trapped and laser−cooled 40Ca+ ion is measured with an optical frequency comb system referenced to a hydrogen maser. A 729−nm laser can be locked to the clock transition about ten hours and the Allan deviation is better than 2×10-14/1000s.
Abstract:The optical frequency of the
4s2S1/2–3d2D5/2 transition in a single trapped and laser−cooled 40Ca+ ion is measured with an optical frequency comb system referenced to a hydrogen maser. A 729−nm laser can be locked to the clock transition about ten hours and the Allan deviation is better than 2×10-14/1000s.
(Tuning forks, frequency standards; frequency measuring and recording instruments; time standards and chronographs)
引用本文:
LIU Qu;;HUANG Yao;;CAO Jian;;OU Bao-Quan;;GUO Bin;**;GUAN Hua;HUANG Xue-Ren;***;GAO Ke-Lin;***
. Frequency Measurement of the Electric Quadrupole Transition in a Single Laser-Cooled 40Ca+[J]. 中国物理快报, 2011, 28(1): 13201-013201.
LIU Qu, , HUANG Yao, , CAO Jian, , OU Bao-Quan, , GUO Bin, **, GUAN Hua, HUANG Xue-Ren, ***, GAO Ke-Lin, ***
. Frequency Measurement of the Electric Quadrupole Transition in a Single Laser-Cooled 40Ca+. Chin. Phys. Lett., 2011, 28(1): 13201-013201.
[1] Dehmelt H 1982 IEEE Trans. Instrum. Meas. 31 83
[2] Margolis H S et al 2004 Science 306 1355
[3] Schneider T, Peik E and Tamm C 2005 Phys. Rev. Lett. 94 230801
[4] Rosenband T et al 2008 Science 319 1808
[5] Chou C W et al 2010 Phys. Rev. Lett. 104 070802
[6] Chwalla M et al 2009 Phys. Rev. Lett. 102 023002
[7] Matsubara K et al 2008 Appl. Phys. Express 1 067011
[8] Shu H L et al 2005 Chin. Phys. Lett. 22 1641
[9] Shu H L et al 2007 Chin. Phys. Lett. 24 1217
[10] Guo B et al 2009 Front. Phys. Chin. 4 144
[11] Guan H et al 2007 Opt. Commum. 274 182
[12] Berkeland D J et al 1998 J. Appl. Phys. 83 5025
[13] Matsubara K et al 2005 Jpn. J. Appl. Phys. 44 229
[14] Drever R W P et al 1983 Appl. Phys. B 31 97
[15] Guan H et al 2011 Opt. Commun. 284 217
[16] Barwood G P et al 2004 Phys. Rev. Lett. 93 133001
[17] Roos C F et al 2006 Nature 443 316
[18] Madej A A et al 2004 Phys. Rev. A 70 012507
[19] Barwood G et al 2001 IEEE Trans. Instrum. Meas. 50 543
[20] Bernard J E et al 1999 Phys. Rev. Lett. 82 3228