Abstract:A superconducting energy recovery linac test facility (PKU-SETF) was built at Peking University, and a 2 K cryogenic system, which is the first closed-loop 2 K cryogenic system for a superconducting accelerator in China, was constructed for the 1.3 GHz 3+1/2 cell dc-SRF injector. The main accelerator consists of two nine-cell TESLA-type superconducting cavities of the PKU-SETF. The commissioning and stable operation of this 2 K cryogenic system was carried out. A helium pressure stability of better than ±0.1 mbar and a total refrigeration capacity of 65 W at a temperature of 2 K was reached.
. [J]. 中国物理快报, 2013, 30(8): 80702-080702.
LIN Lin, HAO Jian-Kui, XIE Hua-Mu, QUAN Sheng-Wen, WEN Xiao-Dong, ZHAO Kui, LIU Ke-Xin. Stable Operation of the 2 K Cryogenic System for the Superconducting Accelerator at Peking University. Chin. Phys. Lett., 2013, 30(8): 80702-080702.
[1] Chen J E, Liu K X and Zhao K 2009 Proc. 14th International Conference on RF Superconductivity (Berlin, Germany, 20–25 September 2009) p 42 [2] Zhu F et al 2007 High Energy Phys. Nucl. Phys.31 496 [3] Schwettman H A et al 1967 IEEE Trans. Nucl. Sci.14336 [4] Chen G B 2003 New Type Low Temp. Technol. (Shanghai Shanghai Jiaotong University Press) p 72 (in Chinese) [5] Chao A W and Tigner M 1998 Handbook of Accelerator Physics and Engineering (Singapore: World Scientific) p 307 [6] Hao J K et al 2006 Chin. Phys. Lett.23 2674 [7] Li S P, Ge R and Wang G P 2008 Chin. Phys. C 32 194 [8] Liu J F 2009 13th ESLS-RF Meeting (Hamburg, Germany, 30 September–1 October 2009) (invited talk)