摘要A new linear phased array on a concave cylindrical transducer is designed for meeting the specific requirements of applications for interstitial thermal ablation. Using the array, a focal line can be generated rapidly and the focal position can be adjusted in the proper range without the use of complex mechanical structures. The focused acoustic field distributions in the axial, radial and azimuthal directions of the transducer are investigated theoretically by numerical simulation. Effects of the focal distance, steering angle, element arc-width, arc-space between adjacent elements and number of elements on the acoustic field are also thoroughly studied. Many important results are obtained.
Abstract:A new linear phased array on a concave cylindrical transducer is designed for meeting the specific requirements of applications for interstitial thermal ablation. Using the array, a focal line can be generated rapidly and the focal position can be adjusted in the proper range without the use of complex mechanical structures. The focused acoustic field distributions in the axial, radial and azimuthal directions of the transducer are investigated theoretically by numerical simulation. Effects of the focal distance, steering angle, element arc-width, arc-space between adjacent elements and number of elements on the acoustic field are also thoroughly studied. Many important results are obtained.
YU Li-Li**;SHOU Wen-De;HUI Chun**
. Theoretical Calculation of a Focused Acoustic Field from a Linear Phased Array on a Concave Cylindrical Transducer[J]. 中国物理快报, 2011, 28(10): 104302-104302.
YU Li-Li**, SHOU Wen-De, HUI Chun**
. Theoretical Calculation of a Focused Acoustic Field from a Linear Phased Array on a Concave Cylindrical Transducer. Chin. Phys. Lett., 2011, 28(10): 104302-104302.
[1] Hynynen K 1992 Med. Phys. 19 979
[2] Bouchoux G, Lafon C, Berriet R, Chapelon J Y, Fleury G and Cathignol D 2008 Ultrasound Med. Biol. 34 607
[3] Nau W H, Diederich C J, and Burdette E C 2001 Med. Phys. 28 1525
[4] Lafon C, Melodelima D, Salomir R and Chapelon J Y 2007 Int. J. Hypertherm. 23 153
[5] Bouchoux G, Owen N, Chavrier F Berrirt R, Fleury G, Chapelon J Y and Lafon C 2010 IEEE Trans. UFFC 57 1086
[6] Lafon C, Melodelima D, Theillère Y, Chapelon J Y and Cathignol D 2002 Med. Phys. 29 290
[7] Makin I R, Mast T D, Faidi W, Runk M M, Barthe P G and Slayton M H 2005 Ultrasound Med. Biol. 31 1539
[8] Deng F Q, Zhang B X, Wang D and Song G P 2006 Chin. Phys. Lett. 23 3297
[9] O'Neil H T 1949 J. Acoust. Soc. Am. 21 516
[10] Foster F S, Arditi M and Hunt J W 1980 J. Acoust. Soc. Am. 68 85
[11] Bobber R J 1977 Underwater Electroacoustic Measurements translated by Zheng S J and Wang H Z (Beijing: National Defense Industry Press) pp 45 143 (in Chinese)
[12] Wooh S C and Shi Y J 1999 Wave Motion 29 245