摘要Neutral beam injection is recognized as one of the most effective means for plasma heating. The preliminary data of ion beam extraction is obtained on the EAST neutral beam injector test-stand. Beam extraction from the ion source of EAST-NBI is verified by measuring the beam current with a Faraday cup and by analyzing the results obtained by means of water calorimetric measurement on the temperature rises of water cooling the accelerator electrodes.
Abstract:Neutral beam injection is recognized as one of the most effective means for plasma heating. The preliminary data of ion beam extraction is obtained on the EAST neutral beam injector test-stand. Beam extraction from the ion source of EAST-NBI is verified by measuring the beam current with a Faraday cup and by analyzing the results obtained by means of water calorimetric measurement on the temperature rises of water cooling the accelerator electrodes.
XU Yong-Jian**, HU Chun-Dong, LIU Sheng, XIE Ya-Hong, LIANG Li-Zhen, JIANG Cai-Chao. Preliminary Experimental Study of Ion Beam Extraction of EAST Neutral Beam Injector[J]. 中国物理快报, 2012, 29(3): 35201-035201.
XU Yong-Jian, HU Chun-Dong, LIU Sheng, XIE Ya-Hong, LIANG Li-Zhen, JIANG Cai-Chao. Preliminary Experimental Study of Ion Beam Extraction of EAST Neutral Beam Injector. Chin. Phys. Lett., 2012, 29(3): 35201-035201.
[1] Wan Y X, Li J G and Weng P D 2006 Plasma Sci. Technol. 8 253
[2] Itoh T, Akino N, Ebisawa N and Grisham L et al 2000 Fusion Eng. Des. 51 1039
[3] Ciric D, Brown D P D, Challis C D and Chuilon B et al 2007 Fusion Eng. Des. 82 610
[4] Ikeda Y and Grp N H 2006 J. Korean Phys. Soc. 49 S43
[5] Naieni A K, Bahrami F, Yasrebi N and Rashidian B 2009 Vacuum 83 1095
[6] Shaw J, Averill R, Kowalski S, Sarkar S, Sibley C, Sobczynski S and Turchinetz W 1998 Proc. 1997 Part. Accelerator Conference (Vancouver, Canada 12-16 May 1997) 1-3 2274