Quantitative Evaluation Methods of In-Line X-Ray Phase Contrast Techniques
-
Abstract
By revealing the relationship between edge visibility and imaging parameters in in-line phase contrast imaging (PCI), we propose a method to quantitatively measure the contribution of absorption and phase shift from acquired images. We also prove that edge visibility will grow with the increasing source-object distance and object-detector distance. The result is validated by relative phase factor and by experiments conducted on a microfocus x-ray source. This method provides a new approach to evaluate in-line PCI images and is helpful for deciding imaging parameters.