Density Fluctuation Measurements Using FIR Interferometer on HL-2A Tokamak
-
ZHOU Yan,
-
LI Lian-Cai,
-
LI Yong-Gao,
-
JIAO Yi-Ming,
-
DENG Zhong-Chao,
-
YI Jiang,
-
LIU Yi,
-
ZHAO Kai-Jun,
-
JI Xiao-Quan,
-
PENG Bei-Bin,
-
YANG Qing-wei,
-
DUAN Xu-Ru,
-
DING Xuan-Tong
-
Abstract
Density fluctuations were first measured in the core region of HL-2A tokamak plasma using a newly developed multi-channel FIR interferometer system. In divertor ohmic discharges, we measured the radial density fluctuation levels of 5%, which increase to 10--20% during the appearance of MHD activity. Most of the power density in the density fluctuation spectrum is directly associated with m=2 tearing modes. The fluctuation levels reduce to 1/3 and plasma confinement is improved during off-axis electron-cyclotron-resonance heating (ECRH).
Article Text
-
-
-
About This Article