Measurement of Enthalpy Relaxation in a Metallic GlassPd77.5 Cu6.0 Si16.5
-
Abstract
Enthalpy relaxation in amorphous Pd77.5 Cu6.0 Si16.5 in sub-Tg temperature region was studied by differential scanning calorimetry (DSC). Enthalpy change due to annealing, which was measured by deducting the effect of glass transition, increased gradually to a saturated value with increasing annealing time (ta). At lower temperatures, enthalpy relaxation exhibited two-stage in ta dependence.
Article Text
-
-
-
About This Article
Cite this article:
DING Xingzhao, HE Yizhen. Measurement of Enthalpy Relaxation in a Metallic GlassPd77.5 Cu6.0 Si16.5[J]. Chin. Phys. Lett., 1994, 11(9): 565-568.
DING Xingzhao, HE Yizhen. Measurement of Enthalpy Relaxation in a Metallic GlassPd77.5 Cu6.0 Si16.5[J]. Chin. Phys. Lett., 1994, 11(9): 565-568.
|
DING Xingzhao, HE Yizhen. Measurement of Enthalpy Relaxation in a Metallic GlassPd77.5 Cu6.0 Si16.5[J]. Chin. Phys. Lett., 1994, 11(9): 565-568.