DETERMINATION OF PRESSURE BROADENING COEFEICIENTS OF NO2 BY LASER MAGNETIC RESONANCE*
-
Abstract
A method which is an indirect measurement of spectral line width using the technique of laser magnetic resonance is described in this letter. The pressure broadening parameters γ° NO2- NO2, He,N2,O2, air were deter- mined to be 5.3±0.5,1.l±0.2,2.7±0.1,1.9±0.2,2.5±0.1MHz/Torr respectively at room temperature.
Article Text
-
-
-
About This Article
Cite this article:
CHEN Yangqin, LIU Yuyan, LI Fengyan, LI Jinrui, HE Kuanglin. DETERMINATION OF PRESSURE BROADENING COEFEICIENTS OF NO2 BY LASER MAGNETIC RESONANCE*[J]. Chin. Phys. Lett., 1988, 5(6): 277-280.
CHEN Yangqin, LIU Yuyan, LI Fengyan, LI Jinrui, HE Kuanglin. DETERMINATION OF PRESSURE BROADENING COEFEICIENTS OF NO2 BY LASER MAGNETIC RESONANCE*[J]. Chin. Phys. Lett., 1988, 5(6): 277-280.
|
CHEN Yangqin, LIU Yuyan, LI Fengyan, LI Jinrui, HE Kuanglin. DETERMINATION OF PRESSURE BROADENING COEFEICIENTS OF NO2 BY LASER MAGNETIC RESONANCE*[J]. Chin. Phys. Lett., 1988, 5(6): 277-280.