GENERAL |
|
|
|
|
Relations between Mass Change and Frequency Shift of a QCM Sensor in Contact with Viscoelastic Medium |
TAN Feng**, HUANG Xian-He |
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731
|
|
Cite this article: |
TAN Feng, HUANG Xian-He 2013 Chin. Phys. Lett. 30 050701 |
|
|
Abstract We investigate frequency shift of a quartz crystal microbalance (QCM) sensor introduced by mass effect, and properties of material of its coated viscoelastic film are discussed. The validity of the Sauerbrey relation cannot be held if the viscoelastic properties of the contacting medium are considered. When the QCM sensor with a viscoelastic film works in the gas phase, the viscoelastic properties will introduce an extra mass effect. While in the liquid phase, the missing mass effect can be observed. The experimental results demonstrate that the QCM sensor is sensitive to the viscoelastic properties of the coating film. Properties of the viscoelastic contacting medium should be considered.
|
|
Received: 04 December 2012
Published: 31 May 2013
|
|
PACS: |
07.75.+h
|
(Mass spectrometers)
|
|
43.25.Zx
|
(Measurement methods and instrumentation for nonlinear acoustics)
|
|
43.35.Ns
|
(Acoustical properties of thin films)
|
|
|
|
|
[1] Lu C and Czanderna A W 1984 Applications of Piezoelectric Quartz Crystal Microbalances (Amsterdam: Elsevier) [2] Sauerbrey G 1959 Z. Phys. 155 206 [3] Voinova M V, Jonson M and Kasemo B 1997 J. Phys.: Condens. Matter 9 7799 [4] Voinova M V, Rodahl M Jonson, M and Kasemo B 1999 Phys. Scr. 59 391 [5] Reed C E, Kanazawa K K and Kaufman J H 1990 J. Appl. Phys. 68 1993 [6] Rodahl M, Hook F, Fredriksson C, Keller C, Voinova M V, Jonson M and Kasemo B 1997 Faraday Discuss. 107 229 [7] Lucklum R and Hauptmann P 1997 Faraday Discuss. 107 123 [8] Johannsmann D, Mathauer K, Wegner G and Knoll W 1992 Phys. Rev. B 46 7808 [9] Lucklum R and Hauptmann P 2000 Sens. Actuators B 70 30 [10] Johannsmann D 2008 Anal. Chem. 80 8891 [11] Borovikov A P 1976 Instrum. Exp. Tech. (USSR) 19 223 [12] Kanazawa K K and Gordon II J G 1985 Anal. Chem. 57 1770 [13] Mason W P 1948 J. Colloid Sci. 3147 [14] Lucklum R, Behling C, Cernosek R W and Martin M J 1997 J. Phys. D 30 346 [15] A Arnau, Y Jimenez and T Sogorb 2001 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 48 1367 [16] Lucklum R, Behling C and Hauptmann P 1999 Anal. Chem. 71 2488 [17] Lucklum R, Behling C and Hauptmann P, Cermosek R W and Martin S J 1998 Sens. Actuators A 66 184 [18] Johnson L, Gupta A K, Ghafoor A, Akin D and Bashir R 2006 Sens. Actuators B 115 189 [19] Gupta A, Akin D and Bashir R 2004 Appl. Phys. Lett. 84 1976 [20] Keller C A and Kasemo B 1998 Biophys. J. 75 1397 [21] Lee J, Jang J, Akin D, Savran C A and Bashir R 2008 Appl. Phys. Lett. 93 013901 [22] Bandey, H L, Martin S J, Cermossek R W and Hillman A R 1999 Anal. Chem. 71 2205 |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|