Chin. Phys. Lett.  2016, Vol. 33 Issue (05): 058502    DOI: 10.1088/0256-307X/33/5/058502
CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY |
Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance Ion Source
Ming-Zhi Guan1,2**, Qiang Hu1,2, Pei-Feng Gao2, Xing-Zhe Wang2, Tong-Jun Yang1, Wei Wu1, Can-Jie Xin2, Bei-Min Wu1,2, Li-Zhen Ma1
1Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000
2Key Laboratory of Mechanics on Western Disaster and Environment, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou 730000
Cite this article:   
Ming-Zhi Guan, Qiang Hu, Pei-Feng Gao et al  2016 Chin. Phys. Lett. 33 058502
Download: PDF(1110KB)   PDF(mobile)(KB)   HTML
Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL II) is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional superconducting ECR magnetic structure, the SECRAL II includes three superconducting solenoid coils that are located inside the superconducting sextupoles. The SECRAL II can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL II generating its self field of $\sim$8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at $ < $200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL II structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the strains developments of a sextupole is reported. Finally, based on our analysis, the stresses and deformations for its assembly of each SECRAL II coil will be further optimized.
Received: 30 December 2015      Published: 31 May 2016
PACS:  85.25.Am (Superconducting device characterization, design, and modeling)  
  85.25.-j (Superconducting devices)  
  74.81.-g (Inhomogeneous superconductors and superconducting systems, including electronic inhomogeneities)  
TRENDMD:   
URL:  
https://cpl.iphy.ac.cn/10.1088/0256-307X/33/5/058502       OR      https://cpl.iphy.ac.cn/Y2016/V33/I05/058502
Service
E-mail this article
E-mail Alert
RSS
Articles by authors
Ming-Zhi Guan
Qiang Hu
Pei-Feng Gao
Xing-Zhe Wang
Tong-Jun Yang
Wei Wu
Can-Jie Xin
Bei-Min Wu
Li-Zhen Ma
[1]Whyte D, Minervini J, LaBombard B, Marmar E, Bromberg L and Greenwald M 2016 J. Fusion Energy 35 41
[2]Qu T, Han Z and Flukiger R 2006 Physica C 444 71
[3]Xie P, Qu T, Huang K, Feng F and Han Z 2014 Mater. Express 4 105
[4]Qu T, Gu C, Huang K, Song H, Zeng P and Han Z 2011 IEEE Trans. Appl. Supercond. 21 2832
[5]Guan M, Wang X, Xin C, Wu W and Ma L 2014 J. Supercond. Novel Magn. 27 1179
[6]Leitner D, Lyneis C, Abbott S, Collins D, Dwinell R, Galloway M, Leitner M and Todd D 2005 Nucl. Instrum. Methods Phys. Res. Sect. B 235 486
[7]Girard A, Hitz D, Melin G, Celona L, Ciavola G, Gammino S, Romano P and Torrisi L 2001 Proc. PAC'01 ( Chicago 1–3 June 2001) p 2409
[8]Guan M, Wang X, Xin C, Zhou Y and Ma L 2015 Chin. Phys. Lett. 32 017401
[9]Ferracin P and Caspi S 2007 Cryogenics 47 595
[10]Krzesinski G, Zagrajek T, Marek P, Dobosz R, Czarkowski P and Kurzyd?owski K 2007 Fusion Eng. Des. Design 82 1574
[11]Vaghar M, Garmestani H and Markiewicz W 1996 J. Appl. Phys. 80 2490
[12]Markiewicz W, Larbalestier D, Weijers H, Voran A, Pickard K, Sheppard W, Jaroszynski J, Xu A, Walsh R, Lu J, Gavrilin A and Noyes P 2012 IEEE Trans. Appl. Supercond. 22 4300704
[13]Guan M Z, Wang X Z, Ma L Z and Zhou Y H 2014 IEEE Trans. Appl. Supercond. 24 4900904
[14]Zhang H, Wang Q, Wang H, Song S, Zhao B, Dai Y, Huang G and Jiang Z 2010 IEEE Trans. Appl. Supercond. 20 1798
[15]Wang Q, Fen Z, Deng F, Huang G, Yan L and Dai Y 2007 IEEE Trans. Appl. Supercond. 17 2377
[16]Wang Q 2013 Practical Design of Magnetostatic Structure Using Numerical Methods (Singapore: Wiley) http://as.wiley.com/WileyCDA/WileyTitle/productCd-1118398149.html
[17]Wang X, Guan M and Ma L 2012 Supercond. Sci. Technol. 25 095009
[18]Guan M, Wang X, Ma L, Zhou Y, Zhao H, Xin C, Yang L, Wu W and Yang X 2013 J. Supercond. Novel Magn. 26 2361
[19]Kim Y, Hahn S, Voccio J, Song J, Bascu?án J and Iwasa Y 2013 IEEE Trans. Appl. Supercond. 23 4300504
[20]Zhang H, Wang Q, Li X, Wang W and Ma J 2010 IEEE Trans. Appl. Supercond. 21 2304
Related articles from Frontiers Journals
[1] Hao Li, Jian-She Liu, Han Cai, Ying-Shan Zhang, Qi-Chun Liu, Gang Li, Wei Chen. True Random Number Generator Realized by Extracting Entropy from a Negative-Inductance Superconducting Quantum Interference Device[J]. Chin. Phys. Lett., 2017, 34(1): 058502
[2] ZHANG Si-Lei, LI Hai-Jie, WEI Lian-Fu, FANG Yu-Rong, WANG Yi-Wen, ZHOU Pin-Jia, WEI Qiang, CAO Chun-Hai, XIONG Xiang-Zheng. Microwave Transmissions through Superconducting Coplanar Waveguide Resonators with Different Coupling Configurations[J]. Chin. Phys. Lett., 2013, 30(8): 058502
[3] ZHAO Na, LIU Jian-She, LI Hao, LI Tie-Fu, and CHEN Wei. Single and Double Superconducting Coplanar Waveguide Resonators[J]. Chin. Phys. Lett., 2012, 29(8): 058502
[4] SHEN Xiao-Fang, YANG Xiao-Yan, YOU Li-Xing,. Performance of Superconducting Nanowire Single-Photon Detection System[J]. Chin. Phys. Lett., 2010, 27(8): 058502
[5] LI Jing, WANG Ming-Jye, SHI Sheng-Cai, Hiroshi Matsuo. Terahertz Detection with Twin Superconductor--Insulator--Superconductor Tunnel Junctions[J]. Chin. Phys. Lett., 2007, 24(2): 058502
Viewed
Full text


Abstract