GENERAL |
|
|
|
|
Preparation and Humidity Sensing Properties of KCl/MCM-41 Composite |
LIU Li1, KOU Li-Ying2, ZHONG Zhi-Cheng3, WANG Lian-Yuan1, LIU Li-Fang4, LI Wei1
|
1State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012 2The Eleventh High School of Changchun City, Changchun 130061 3College of Computer Science and Technology, Jilin University, Changchun 130012 4College Instrumentation and Electrical Engineering, Jilin University, Changchun 130026 |
|
Cite this article: |
LIU Li, KOU Li-Ying, ZHONG Zhi-Cheng et al 2010 Chin. Phys. Lett. 27 050701 |
|
|
Abstract KCl/mobil composition of matter-41 (MCM-41) composite has been synthesized via a heat-treating process and characterized by x-ray diffraction, high resolution transmission electron microscopy, and nitrogen adsorption/desorption isotherms. In contrast with pure MCM-41, KCl/MCM-41 composite exhibits improved humidity sensing properties within the relative humidity range of 11-95%. The impedance of KCl/MCM-41 composite changes by about four orders of magnitude over the whole humidity range with the response time and the recovery times are about 30 s and 35 s, respectively. Small humidity hysteresis and good stability are also observed based on our product. These results make our product a good candidate in fabricating humidity sensors with high performances and low synthetic complexity.
|
Keywords:
07.07.Df
82.47.Rs
|
|
Received: 09 October 2009
Published: 23 April 2010
|
|
PACS: |
07.07.Df
|
(Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing)
|
|
82.47.Rs
|
(Electrochemical sensors)
|
|
|
|
|
[1] Wang S, Wang Z, Liu X and Zhang L 2008 Sensors Actuators B 131 318 [2] Zhang Y G, Gu Y, Zhang X J, Li A Z and Tian Z B 2008 Chin. Phys. Lett. 25 3246 [3] Sang X Z, Yu C X, Yan B B, Ma J X, Meng Z F, Mayteevarunyoo T and Lu N G 2006 Chin. Phys. Lett. 23 3202 [4] Wang X H, Wang X L, Feng C, Xiao H L, Yang C B, Wang J X, Wang B Z, Ran J X and Wang C M 2008 Chin. Phys. Lett. 25 266 [5] Huang J T, Huang X G and Zhao H W 2008 Chin. Phys. Lett. 25 1329 [6] Feng C, Wang X L, Yang C B, Xiao H L, Zhang M L, Jiang L J, Tang J, Hu G X, Wang J X and Wang Z G 2008 Chin. Phys. Lett. 25 3025 [7] Alireza K, 2009 Chin. Phys. Lett. 26 060701 [8] Liu L, Zhang T, Li S C, Wang L Y, Fan H T and Li W 2009 Chin. Phys. Lett. 26 100702 [9] Upadhyay S and Kavitha P 2007 Mater. Lett. 61 1912 [10] Kuang Q, Lao C, Wang Z L, Xie Z and Zheng L 2007 J. Am. Chem. Soc. 129 6070 [11] Ozkan E, Lee S H, Liu P, Tracy C E, Tepehan F Z, Pitts J R and Deb S K 2002 Solid State Ionics 149 139 [12] Suzuki T M, Yamamoto M, Fukumoto K, Akimoto Y and Yano K 2007 J. Catal. 251 249 [13] Bearzotti A, Bertolo J M and Innocenzi P 2003 Sensors Actuators B 95 107 [14] Innocenzi P, Martucci A, Guglielmi M, Bearzotti A, Traversa E and Pivin J C 2001 J. Eur. Ceram. Soc. 21 1985 [15] Kawahara K, Kohiki S, Yoshitomi T, Nishi S, Shimooka H, Mitome M, Bando Y, Shishido T and Oku M 2008 Mater. Lett. 62 3682 [16] Qi Q, Zhang T and Wang L 2008 Appl. Phys. Lett. 93 023105 [17] Yin L F, Wang F F and Fu J W 2007 Mater. Lett. 61 3119 [18] Kulwicki B M 1991 J. Am. Ceram. Soc. 74 697 [19] Anderson J H and Parks G A 1968 J. Phys. Chem. 72 3662 [20] Casalbore-Miceli G, Yang M J, Camaioni N, Mari C M, Li Y, Sun H and Ling M 2000 Solid State Ionics 131 311
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|