Chin. Phys. Lett.  2002, Vol. 19 Issue (8): 1100-1102    DOI:
Original Articles |
A New Method of X-Ray Holographic Tomography
XIE Hong-Lan;CHEN Jian-Wen;GAO Hong-Yi;LU Pei-Xiang;XU Zhi-Zhan
Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, P. O. Box 800-211, Shanghai 201800
Cite this article:   
XIE Hong-Lan, CHEN Jian-Wen, GAO Hong-Yi et al  2002 Chin. Phys. Lett. 19 1100-1102
Download: PDF(277KB)  
Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract A new method of x-ray holographic tomography, called the pre-amplified x-ray holographic tomography, is proposed to develop x-ray three-dimensional microscopic imaging technique. In this method, the key component is a micro zone plate taken as an imaging element like an optic lens in x-ray field. Some advantages of the method are shown by a numeric example. The method may make it possible to obtain x-ray microscopic imaging of biological specimens at high resolution in three dimensions.
Keywords: 42.30.Wb      42.40.Ht      07.85.Tt     
Published: 01 August 2002
PACS:  42.30.Wb (Image reconstruction; tomography)  
  42.40.Ht (Hologram recording and readout methods)  
  07.85.Tt (X-ray microscopes)  
TRENDMD:   
URL:  
https://cpl.iphy.ac.cn/       OR      https://cpl.iphy.ac.cn/Y2002/V19/I8/01100
Service
E-mail this article
E-mail Alert
RSS
Articles by authors
XIE Hong-Lan
CHEN Jian-Wen
GAO Hong-Yi
LU Pei-Xiang
XU Zhi-Zhan
Related articles from Frontiers Journals
[1] YANG Jing,DU Shi-Feng,ZHANG Jing-Yuan,*,CAO Dong,CUI Da-Fu,PENG Qin-Jun,XU Zu-Yan*. Tomographic Imaging and Three-Dimensional Reconstruction Based on a High-Gain Optical Parametric Amplifier[J]. Chin. Phys. Lett., 2012, 29(5): 1100-1102
[2] LIN Jie, **, CHENG Jing . Lensless Ghost Diffraction with Partially Coherent Sources: Effects of the Source Size, Transverse Coherence, Detector Size and Defocusing Length[J]. Chin. Phys. Lett., 2011, 28(9): 1100-1102
[3] ZHANG Yi-Zhuo, WANG Da-Yong, **, WANG Yun-Xin, TAO Shi-Quan . Automatic Compensation of Total Phase Aberrations in Digital Holographic Biological Imaging[J]. Chin. Phys. Lett., 2011, 28(11): 1100-1102
[4] YANG Si-Hua, YIN Guang-Zhi, XING Da. Pharmacokinetic Monitoring of Indocyanine Green for Tumor Detection Using Photoacoustic Imaging[J]. Chin. Phys. Lett., 2010, 27(9): 1100-1102
[5] XU Xian-Feng, CAI Lu-Zhong, WANG Yu-Rong, LI Dai-Lin. Accurate Phase Shift Extraction for Generalized Phase-Shifting Interferometry[J]. Chin. Phys. Lett., 2010, 27(2): 1100-1102
[6] QUAN Guo-Tao, GONG Hui, FU Jian-Wei, DENG Yong** . Photon-Measurement Density Function of Fluorescence Molecular Tomography Based on Direct Method[J]. Chin. Phys. Lett., 2010, 27(11): 1100-1102
[7] LU Xiao-Wei, LI Jing-Zhen, CHEN Hong-Yi . Improvement of Quality of Reconstructed Images in Multi-Frame Fresnel Digital Holography[J]. Chin. Phys. Lett., 2010, 27(10): 1100-1102
[8] WANG Gang, FANG Jie-Ran, WANG Hong-Jin. Focusing of a Flat Left-Handed Metamaterial Lens in a Heterogeneous and Lossy Medium[J]. Chin. Phys. Lett., 2009, 26(5): 1100-1102
[9] CHEN Bo, GENG Ze-Xun, SHEN Jun, YANG Yang. Point Spread Function Estimation for a Turbulence-Degenerated Image Based on Àtrous Wavelet Transform[J]. Chin. Phys. Lett., 2009, 26(4): 1100-1102
[10] JIANG Lai-Xin, WU Yi-Qun, WANG Yang, WEI Jing-Song, GAN Fu-Xi. Low-Power Super-resolution Readout with Antimony Bismuth Alloy Film as Mask layer[J]. Chin. Phys. Lett., 2009, 26(2): 1100-1102
[11] YI Tao, ZHANG Jia-Sen, ZHU Yi-Chao, GONG Qi-Huang. Crosstalk Noise Reduction in Shift-Multiplexed Holographic Storage System Using Multiple Point Sources[J]. Chin. Phys. Lett., 2008, 25(8): 1100-1102
[12] F. Shahzad, S. A. Siddiqi, J. Zhou. Fabrication and Characterization of SmCo5/Fe65Co35 and SmCo5/Fe Composite Spring Exchange Magnets[J]. Chin. Phys. Lett., 2008, 25(7): 1100-1102
[13] WANG Qiong, YAN Chang-Chun, ZHANG Ling-Ling, CUI Yi-Ping. Effects of Parameter Modulation on Near-Field Imaging in Photonic Crystal Consisting of Alternately Left-Handed Material and Right-Handed Material[J]. Chin. Phys. Lett., 2008, 25(12): 1100-1102
[14] FANG Jie-Ran, GONG Yu, DONG Xiao-Ting, WANG Gang. Impacts of Refraction Index Mismatch on Performance of Target Detection and Imaging by Using Flat LHM Lens[J]. Chin. Phys. Lett., 2008, 25(1): 1100-1102
[15] DAI Cui-Xia, YU Ying-Jie, LIU De-An, LIU Li-Ren. Optimal Recording Wavelength for Nonvolatile Photorefractive Holograms in Ce:Cu:LiNbO[J]. Chin. Phys. Lett., 2007, 24(3): 1100-1102
Viewed
Full text


Abstract