1Key Laboratory of Functional Materials and Devices for Special Environments, Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi 830011 2Xinjiang Key Laboratory of Electronic Information Material and Device, Urumqi 830011 3University of Chinese Academy of Sciences, Beijing 100049
Abstract:The synergism effect of total ionizing dose (TID) on a single event transient (SET) in a bipolar comparator is investigated. Experimental results show that the shapes of the SET are considerably influenced by the TID accumulated in low dose rates. The variation tendency of SET shapes can be accurately simulated by temperature switching irradiation. The mechanism of this synergism effect is also analyzed in brief via the operating schematic of a comparator. After the accumulation of 100 krad(Si), the lower tendency of negative SET can be attributed to the degeneration of $\beta$. The change tendency of a positive SET, either lower or higher, is dependent on the load condition that limits the output range of the comparator.