1Key Laboratory for the Physics and Chemistry of Nanodevices and Department of Electronics, Peking University, Beijing 100871 2Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055 3Chang'an Communication Technology Co., Ltd., Beijing 102209 4SIP-UCLA Institute for Technology Advancement, Suzhou 215123
Abstract:In field emission under a non-dc voltage, a displacement current is inevitable due to charging the cathode–anode condenser. Under an often-used square voltage pulse, in which the voltage rises from zero to a certain value abruptly, the charging current in the circuit is very large at the rising and falling edges. This large charging current makes measurement of the actual emissive current from the cathode difficult, constitutes a threat to the components in the circuit and causes attenuation of the emissive current within the pulse. To alleviate these drawbacks, trapezoid voltage pulses, whose rising edges are extended dramatically in comparison with square voltage pulses, are employed to extract the field emission. Under a trapezoid voltage pulse, the charging current is clearly lowered as expected. Furthermore, the heat generated by the charging current under the trapezoid voltage pulse is much smaller than that under the square voltage pulse. Hence the emissive current does not show any attenuation within the pulse. Finally, the average emissive currents are found to decrease with the repetition frequency of the pulses.