High-Precision Calibration of Electron Beam Energy from the Hefei Light Source Using Spin Resonant Depolarization
LAN Jie-Qin1,2**, XU Hong-Liang1
1National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 2Department of Mathematics and Physics, Fujian University of Technology, Fuzhou 350108
Abstract:The electron beam energy at the Hefei Light Source (HLS) in the National Synchrotron Radiation Laboratory is highly precisely calibrated by using the method of spin resonant depolarization for the first time. The spin tune and the beam energy are determined by sweeping the frequency of a radial rf stripline oscillating magnetic field to artificially excite a spin resonance and depolarize the beam. The resonance signal is recognized by observing the sudden change of the Touschek loss counting rate of the beam. The possible systematic errors of the experiment are presented and the accuracy of the calibrated energy is shown to be about 10?4. A series of measurements show that the energy stability of the machine is of the order of 9×10?3.