Development of a Real-Time Ion Spectrometer with a Scintillator for Laser-Driven Ion Acceleration Experiments
XU Miao-Hua1**, LI Hong-Wei1, LIU Bi-Cheng2,3, LIU Feng2, SU Lu-Ning2, DU Fei2, ZHANG Lu2, ZHENG Yi2, MA Jing-Long2, David Neely4, Paul McKenna5, WANG Zhao-Hua2, WEI Zhi-Yi2, YAN Xue-Qing3, LI Yu-Tong2**, LI Ying-Jun1, ZHANG Jie2,6
1Department of Physics, China University of Mining & Technology (Beijing), Beijing 100083 2Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 3State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 4Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot OX11 0QX, UK 5SUPA, Department of Physics, University of Strathclyde, Glasgow G4 0NG, UK 6Department of Physics, Shanghai Jiao Tong University, Shanghai 200240
Development of a Real-Time Ion Spectrometer with a Scintillator for Laser-Driven Ion Acceleration Experiments
XU Miao-Hua1**, LI Hong-Wei1, LIU Bi-Cheng2,3, LIU Feng2, SU Lu-Ning2, DU Fei2, ZHANG Lu2, ZHENG Yi2, MA Jing-Long2, David Neely4, Paul McKenna5, WANG Zhao-Hua2, WEI Zhi-Yi2, YAN Xue-Qing3, LI Yu-Tong2**, LI Ying-Jun1, ZHANG Jie2,6
1Department of Physics, China University of Mining & Technology (Beijing), Beijing 100083 2Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 3State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 4Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot OX11 0QX, UK 5SUPA, Department of Physics, University of Strathclyde, Glasgow G4 0NG, UK 6Department of Physics, Shanghai Jiao Tong University, Shanghai 200240
摘要A real-time ion spectrometer mainly based on a high-resolution Thomson parabola and a plastic scintillator is designed and developed. The spectrometer is calibrated by protons from an electrostatic accelerator. The feasibility and reliability of the diagnostics are demonstrated in laser-driven ion acceleration experiments performed on the XL-II laser facility. The proton spectrum extrapolated from the scintillator data is in excellent agreement with the CR39 spectrum in terms of beam temperature and the cutoff energy. This real-time spectrometer allows an online measurement of the ion spectra in single shot, which enables efficient and statistical studies and applications in high-repetition-rate laser acceleration experiments.
Abstract:A real-time ion spectrometer mainly based on a high-resolution Thomson parabola and a plastic scintillator is designed and developed. The spectrometer is calibrated by protons from an electrostatic accelerator. The feasibility and reliability of the diagnostics are demonstrated in laser-driven ion acceleration experiments performed on the XL-II laser facility. The proton spectrum extrapolated from the scintillator data is in excellent agreement with the CR39 spectrum in terms of beam temperature and the cutoff energy. This real-time spectrometer allows an online measurement of the ion spectra in single shot, which enables efficient and statistical studies and applications in high-repetition-rate laser acceleration experiments.
(Plasma production and heating by laser beams (laser-foil, laser-cluster, etc.))
引用本文:
XU Miao-Hua**;LI Hong-Wei;LIU Bi-Cheng;LIU Feng;SU Lu-Ning;DU Fei;ZHANG Lu;ZHENG Yi;MA Jing-Long;David Neely;Paul McKenna;WANG Zhao-Hua;WEI Zhi-Yi;YAN Xue-Qing;LI Yu-Tong**;LI Ying-Jun;ZHANG Jie;
. Development of a Real-Time Ion Spectrometer with a Scintillator for Laser-Driven Ion Acceleration Experiments[J]. 中国物理快报, 2011, 28(9): 95203-095203.
XU Miao-Hua**, LI Hong-Wei, LIU Bi-Cheng, LIU Feng, SU Lu-Ning, DU Fei, ZHANG Lu, ZHENG Yi, MA Jing-Long, David Neely, Paul McKenna, WANG Zhao-Hua, WEI Zhi-Yi, YAN Xue-Qing, LI Yu-Tong**, LI Ying-Jun, ZHANG Jie,
. Development of a Real-Time Ion Spectrometer with a Scintillator for Laser-Driven Ion Acceleration Experiments. Chin. Phys. Lett., 2011, 28(9): 95203-095203.
[1] Key M H et al 2006 Fusion Sci. Technol. 49 440
[2] Romagnani L et al 2005 Phys. Rev. Lett. 95 195001
[3] Borghesi M et al 2006 Fusion Sci. Technol. 49 412
[4] Fuchs J et al 2007 Phys. Rev. Lett. 99 015002
[5] Lee K et al 2008 Phys. Rev. E 78 056403
[6] Henig A et al 2009 Phys. Rev. Lett. 103 245003
[7] Palmer C A J et al 2011 Phys. Rev. Lett. 106 14801
[8] Hegelich B M et al 2006 Nature 439 441
[9] Toncian T et al 2006 Science 312 410
[10] Chen M et al 2009 Phys. Rev. Lett. 103 24801
[11] Mančić A et al 2008 Rev. Sci. Instrum. 79 073301
[12] Schowoerer H et al 2006 Nature 439 445
[13] Harres K et al 2008 Rev. Sci. Instrum. 79 093306
[14] Carroll D C, Brummitt P A, Neely D et al 2010 Nucl. Instrum. Methods Phys. Res. A 620 23
[15] Carroll D C, Jones K, Robson L et al 2005/2006 Central Laser Facility Annual Report 16–20
[16] O'Rielly G V, Kolb N R and Pywell R E 1996 Nucl. Instrum. Methods Phys. Res. A 368 745
[17] Saraf S K, Brient C E, Egun P M, Grimes S M, Mishra V and Pedroni R S 1988 Nucl. Instrum. Methods Phys. Res. A 268 200