1Key Display Laboratory of Science and Technology of Sichuan, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 2Institute of Chemistry and Materials, Sichuan Normal University, Chengdu 610081
摘要Aiming at the problem of luminance uniformity for injection electroluminescent display panels, we present a new scan method for display panels according to successive scans theory. First, on the basis of the number of pixels requiring light emitting in one frame period, we adjust the scan time for each row. Secondly, for ensuring image transmission synchronization, the frame period must to be a constant. We adopt a 64×32 LED display panel as an example to expound the new scan method and we obtain the good result that the reduce amplitude of luminance non-uniformity is 31.34% and the increase amplitude of the average luminance value is 7.8258%.
Abstract:Aiming at the problem of luminance uniformity for injection electroluminescent display panels, we present a new scan method for display panels according to successive scans theory. First, on the basis of the number of pixels requiring light emitting in one frame period, we adjust the scan time for each row. Secondly, for ensuring image transmission synchronization, the frame period must to be a constant. We adopt a 64×32 LED display panel as an example to expound the new scan method and we obtain the good result that the reduce amplitude of luminance non-uniformity is 31.34% and the increase amplitude of the average luminance value is 7.8258%.
OU Peng;YANG Gang**;JIANG Quan;WANG Jun;HU Jian-Hua;WU Qi-Peng;LUO Kai-Jun**
. A Successive Scans Method of Adjusting Scan-Time for Injection Electroluminescent Display Panels[J]. 中国物理快报, 2011, 28(4): 44205-044205.
OU Peng, YANG Gang**, JIANG Quan, WANG Jun, HU Jian-Hua, WU Qi-Peng, LUO Kai-Jun**
. A Successive Scans Method of Adjusting Scan-Time for Injection Electroluminescent Display Panels. Chin. Phys. Lett., 2011, 28(4): 44205-044205.
[1] Haldi A, Kim J B, Domercq B, Kulkarni A P, Barlow S, Gifford A P, Jenekhe S A, Marder S R and Kippelen B 2009 IEEE J. Display Technol. 5 120
[2] Lin C J, Huang H L, Tseng M R and Cheng C H 2009 IEEE J. Display Technol. 5 236
[3] Riedl T, Görrn P and Kowalsky W 2009 IEEE J. Display Technol. 5 501
[4] Ono S, Miwa K, Maekawa Y and Tsujimura T 2007 IEEE Trans. Electron Devices 54 462
[5] Hwang S J, Tseng M C, Hwang K C and Yu H H 2007 IEEE J. Display Technol. 3 253
[6] Liu X Q, Zhang T, Wang L J, Xia Z Q, Li M Y and Liu S Y 2008 IEEE J. Display Technol. 4 229
[7] Sambandan S and Nathan A 2007 IEEE J. Display Technol. 3 284
[8] Ashtiani S J and Nathan A 2006 IEEE J. Display Technol. 2 258
[9] Lu H Y, Chang T C, Tai Y H, Liu P T and Chi S 2007 IEEE J. Display Technol. 3 398
[10] Lin C L, Tsai T T and Chen Y C 2008 IEEE J. Display Technol. 4 54
[11] Ashtiani S J and Nathan A 2009 IEEE J. Display Technol. 5 257
[12] Ou P, Yang G, Jiang Q, Yu J S, Wu Q P, Shang F H, Yin W, Wang J, Zhong J and Luo K J 2009 Optoelectron. Lett. 5 0329
[13] Park J, Lee J H, Shin D C and Park S H 2009 IEEE J. Display Technol. 5 306