摘要The present analysis is concerned with flow reversal phenomena of the fully-developed laminar combined free and forced MHD convection in a vertical parallel-plate channel. The effect of viscous dissipation is taken into account. Flow reversal adjacent to the cold (or hot) wall is found to exist within the channel as Gr/Re is above (or below) a threshold value. Parameter zones for the occurrence of reversed flow are presented.
Abstract:The present analysis is concerned with flow reversal phenomena of the fully-developed laminar combined free and forced MHD convection in a vertical parallel-plate channel. The effect of viscous dissipation is taken into account. Flow reversal adjacent to the cold (or hot) wall is found to exist within the channel as Gr/Re is above (or below) a threshold value. Parameter zones for the occurrence of reversed flow are presented.
[1] Tao L N 1960 ASME J. Heat Transfer 82 233 [2] Habchi S and Acharya S 1986 Numer. Heat Transfer A 9 605 [3] Aung W and Worku G 1986 ASME J. Heat Transfer 108 485 [4] Cheng C H, Kou H S and Huang W H 1990 J. Thermophys. Heat Transfer 4 375 [5] Hamadah T T and Wirtz R A 1991 ASME J. Heat Transfer 113 507 [6] Jones A T and Ingham D B 1994 Numer. Heat Transfer A 25 57 [7] Grosan T, Pop R and Pop I 2009 Heat Mass Transfer 45 503 [8] Sparrow E M, Chrysler G M and Azevedo L F 1984 ASME J. Heat Transfer 106 325 [9] Gau C, Yih K A and Aung W 1992 ASME J. Heat Transfer 114 928 [10] Barletta A 1998 Int. J. Heat Mass Transfer 41 3501 [11] Magyari E 2009 Heat Mass Transfer 45 1473 [12] Umavathi J C and Malashetty M S 2005 Int. J. Non-Linear Mech. 40 91 [13] Barletta A and Celli M 2008 Int. J. Heat Mass Transfer 51 6110 [14] Pop I, Grosan T and Cornelia R 2010 Commun. Nonlinear Sci. Numer. Simulat. 15 471