Abstract: We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.
(Physiology of eye; optic-nerve structure and function)
引用本文:
WANG Wei;WANG Zhao-Qi;WANG Yan;ZUO Tong;ZHAO Kan-Xing. Measurements of AIM for Visible Wavelength Based on Individual Eye Model[J]. 中国物理快报, 2006, 23(12): 3263-3266.
WANG Wei, WANG Zhao-Qi, WANG Yan, ZUO Tong, ZHAO Kan-Xing. Measurements of AIM for Visible Wavelength Based on Individual Eye Model. Chin. Phys. Lett., 2006, 23(12): 3263-3266.