摘要A simple method to detect mercury ions confined in a Paul trap has been developed by resonant ejection. In this method, frequency of the additional ejection ac voltage is scanned instead of the amplitude of the rf drive voltage in conventional methods. It is possible not only to observe the spectra of the secular oscillation of the trapped ions directly, but also to eject the confined ions from the trap mass-selectively.
Abstract:A simple method to detect mercury ions confined in a Paul trap has been developed by resonant ejection. In this method, frequency of the additional ejection ac voltage is scanned instead of the amplitude of the rf drive voltage in conventional methods. It is possible not only to observe the spectra of the secular oscillation of the trapped ions directly, but also to eject the confined ions from the trap mass-selectively.
(Effects of atomic and molecular interactions on electronic structure)
引用本文:
WANG Wen-Min0g;SHE Lei;LI Jiao-Mei;GAO Ke-Lin. Detection of Isotopes of Mercury Ions by Resonant Ejection in Paul Trap[J]. 中国物理快报, 2007, 24(7): 1919-1921.
WANG Wen-Min0g, SHE Lei, LI Jiao-Mei, GAO Ke-Lin. Detection of Isotopes of Mercury Ions by Resonant Ejection in Paul Trap. Chin. Phys. Lett., 2007, 24(7): 1919-1921.
[1] Paul W et al 1953 Z. Naturforsch. A 8 448 [2] Dawson P H 1995 Quadrupole Mass Spectrometry and ItsApplications (New York: AIP) [3] Flford J E, Hoa D N, Hughes R J, March R E, Bonner R F and Wang G J1980 J. Vac. Sci. Technol. 17 829 [4] Hidefumi H and Toshijiko K 2001 Rev. Sci. Instrum. 72 7 [5] Prestage J D, Dick G J and Maleki L 1987 JPL Trapped ion FrequencyStandard Development: IEEE Annual Frequency Control Symposium p20 [6] Williams J D et al 1991 Proc. 39th ASMS Conf. Mass Spectrosc.Allied Topics TN 1481 [7] Cai Y, Peng W P, Kuo S J and Chang H C 2002 Int. J. MassSpectrom. 214 63 [8] Louris J N, Brodbelt J S, Cooks R G, Glish G L and McLuckey S A1990 Int. J. Mass Spectom. Ion Processes 96 117