摘要We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.
Abstract:We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.
LIU Guo-Bin;DU Run-Chang;LIU Chao-Yang;GU Si-Hong. CPT Magnetometer with Atomic Energy Level Modulation[J]. 中国物理快报, 2008, 25(2): 472-474.
LIU Guo-Bin, DU Run-Chang, LIU Chao-Yang, GU Si-Hong. CPT Magnetometer with Atomic Energy Level Modulation. Chin. Phys. Lett., 2008, 25(2): 472-474.
[1] Kominis K et al 2003 Nature 422 596 [2] Robbes D 2006 Sensors and Actuators A 129 86 [3] Budker D et al 1998 Phys. Rev. Lett. 81 5788 [4] Budker D et al 2000 Phys. Rev. A 62 043403 [5] Budker D et al 2002 Phys. Rev. A 65 055403 [6] Arimondo E 1996 Prog. Opt. 35 257 [7] Scully M O and Fleischhauer M 1992 Phys. Rev. Lett. 691360 [8] Fleischhauer M and Scully M O 1994 Phys. Rev. A 49 1973 [9]Hwang Lee, Fleischhauer M and Scully M O 1998 Phys. Rev. A 58 2587 [10] Schwindt P D D et al 2004 Appl. Phys. Lett. 85 6409 [11] Knappe S et al 2006 J. Opt. A: Pure Appl. Opt. 8 S318 [12] Xia H et al 2006 Appl. Phys. Lett. 89 211104 [13] Farthing W H and Folz W C 1967 Rev. Sci. Instrum. 381023 [14] Vanier J 2005 Appl. Phys. B 81 421 [15] Du R C et al 2008 Spectroscopy and Spectral Analysis(accepted) (in Chinese) [16] Bevilacqua G et al 2005 Phys. Rev. Lett. 95 123601 [17] Merimaa M et al 2003 J. Opt. Soc. Am. B 20 273 [18] DENG J L et al 2006 Chin. Phys. Lett. 23 1745 [19] Knappe S et al 2004 Appl. Phys. Lett. 85 1460 [20] Lutwak R et al 2005 The MAC-A Miniature Atomic Clock, 37thannual Precise Time and Time Interval $($PTTI$)$ Meeting (Vancouver, BC,Canada) p 752 [21] Vanier J and Audoin C 1989 The Quantum Physics of AtomicFrequency Standards (Bristol: IOP Publishing) p 37 [22] Levi F et al 2000 Eur. Phys. J. D 12 53